- ページ 21

ストレージ Fujitsu Eternus DX90 S2のPDF 設定マニュアルをオンラインで閲覧またはダウンロードできます。Fujitsu Eternus DX90 S2 38 ページ。 Server connection. (fibre channel) for aix
Fujitsu Eternus DX90 S2 にも: ユーザーマニュアル (35 ページ), ユーザーマニュアル (42 ページ), マニュアル (18 ページ), セットアップ (20 ページ), 設定マニュアル サーバー接続 (13 ページ), ハードウェアのインストール (23 ページ), 設定マニュアル (28 ページ), 設定マニュアル (15 ページ)

Fujitsu Eternus DX90 S2 設定マニュアル
Chapter 8
Installing Drivers and Setting Up the Server
8.1

Installing the Driver

Install the necessary drivers and patches following the Fibre Channel card installation guide.
8.2

Setting Up the Driver Parameters

8.2.1

For AIX Configurations (Configurations other than a VIOS/VIOC Configuration)

Use the "smit" command and other commands to set the driver parameters.
If an "fscsiN" entry (where "N" is a number) corresponding to the Fibre Channel card is displayed, delete
the hdisk device (child device of the fscsiN device) temporarily using the "rmdev" command to change the
fscsiN device parameter.
The deleted hdisk device (child device of the fscsiN device) is recreated after the server is rebooted or
when the "cfgmgr" command is executed. Enter the target fscsi number for "N".
For a SAN Boot configuration, apply the change only to the database without deleting the hdisk device
and then reboot the server.
# rmdev -p fscsiN
Set the parameter as shown in the following table.
Parameter
init_link
num_cmd_elems
*1: Recommended value = 1024 ¸ (number of Fibre Channel ports that are connected to a single CA port)
(Round the result down)
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for AIX
Setting target
fcs
fcs
21
Copyright 2018 FUJITSU LIMITED
Setting value
For direct connections,
select [al].
For switch connections,
select [pt2pt].
Arbitrary (*1)
(Up to 1024 for each FC
port of the ETERNUS
DX/AF)
Remarks
This setting is fixed to "Au-
to" for some Fibre Channel
cards (e.g. 5735), and can-
not be changed. Use those
HBAs as they are, in the
"Auto" setting.
P3AM-3782-23ENZ0