Chapter 4
The server information registered in the ETERNUS Disk storage system should be checked.
A variety of commands are used to check the following server information.
iSCSI Software Initiator
Since iSCSI Software Initiator is provided with the OS, installation is not required.
Check the SUNWiscsiu and SUNWiscsir packages using the "pkginfo" command.
iSCSI Initiator name
Execute the following command:
The iSCSI Initiator name is displayed in the "Initiator node name" column.
Server-side LAN card IP address for connecting to the ETERNUS Disk storage system
Execute the following command:
Set this IP address if it is not already set.
Initiator CHAP Name
The Initiator CHAP Name is the user name for unidirectional CHAP authentication, and is not
required if CHAP authentication is not used.
Execute the following command:
The Initiator CHAP Name is displayed in the "CHAP Name" column of the applicable target
information.
P3AM-4182-03ENZ0
Server Connection Guide (iSCSI) for Oracle Solaris
Checking the Server Information
# iscsiadm list initiator-node
# ifconfig -a
# iscsiadm list initiator-node
12