冷蔵庫 AEG 3151のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。AEG 3151 32 ページ。 Refrigerator/freezer combination
The following table shows which ambient temperature is correct for
each climate classification:
Climate classification
If installation next to a source of heat is unavoidable, the following
minimum clearances must be maintained at the sides of the appliance:
– for electric cookers 3 cm;
– for oil and coal fired ranges 30 cm.
If these clearances cannot be maintained a heat insulating pad is requi-
red between the cooker and the refrigeration appliance.
The refrigerator/freezer needs ventilation
Air is fed under the door through the
vent slots in the base and is exhausted
upwards along the back wall. To ensure
proper air circulation never cover or
alter the vent openings.
Important! If the appliance is installed
under a hanging cabinet, a clearance of
at least 10 cm between the top of the
appliance and the cabinet above it must
be maintained.
Please check whether, after installing
your appliance and especially after
reversing the door, the door seal seals
tightly. A badly fitting door seal may
lead to heavy frosting and a higher
power consumption (see also "What to
do if ...").
Appliance Alignment
0
1. The appliance must be level. Please compensate for unevenness in the
floor by turning the two adjustable feet at the front.
SN
N
ST
T
for an ambient temperature of
+10 to +32 °C
+16 to +32 °C
+18 to +38 °C
+18 to +43 °C
Installation