- ページ 10
マザーボード Fujitsu SK-96620_350-64PMC(1)のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Fujitsu SK-96620_350-64PMC(1) 47 ページ。 F²mc-16lx/fx family, mb96620/350 series, mb90350 series
2 Installation
Remove carefully the board from the shipping carton.
Check first if there are any damages before power on the evaluation board.
For the power supply a DC input voltage of 9 V – 12 V is recommended. The positive
voltage (+) must be connected to the centre, and ground (GND) must be connected to
the shield of the connector X12!
After power-on (JP43), the green power-on LEDs (D16, D17 and D18) should be lit. If the
LEDs do not light up, switch off the power supply and check input polarity and current
capability of the DC supply used. Please do not look directly into the LEDs to prevent
harming your eyes.
The in-circuit programming allows the user to program own applications into the Flash
memory. The procedures for Flash programming are described in chapter 5.
If the board shall be used as a MB963xx or 16LX emulator target board, switch off the power
supply and remove the microcontroller from the socket. Now the probe cable can be
mounted on the socket. Take care of the pin 1 marking on the socket and fasten the probe
cable with the provided screws.
Do not use any other probe cable than MB2198-504 or MB2147-540 only!
Connect the probe cable to the MCU family specific emulation Adapter Board. Check all
jumper settings of the evaluation board, the Probe Cable, and the Adapter Board.
On the basis of the MB963xx/16LX microcontroller turning on the emulation system, the
principle of the power-up sequence is described:
1. Power up the Emulator Main Unit (MB2198-01-E)
2. Power up the Adapter Board (MB2198-500), if needed
3. Power up the target Board (SK-96620_350-64PMC)
To turn off the system, switch off the components in reverse order, beginning with the target
Board.
Please refer to the corresponding user manuals and application notes for the emulator how
to set up the emulator system. After power on the „UVCC‟-LED of the emulator must be on.
Note:
Some customers experience connectivity problems when connecting the MCU into
the socket adapter. Only the small red screwdriver available in your box should be
used to connect the cover (HQPACK) onto the socket (NQPACK).
If the four screws are not tightening equally, then it may cause a poor contact.
Do not screw the cover too tight (max 0.054 Nm). If you have connectivity problems
then please loosen the screws and tighten again the screws equally.
Do not clean NQPACK, YQPACK, and YQSOCKET with steam. Cleaning material will
contaminate inside of connector.
© Fujitsu Semiconductor Europe GmbH
SK-96620_350-64PMC(1) User Guide
Chapter 2 Installation
- 10 -
UG-960028-12