- ページ 6

オーブン Indesit I6G52/UKのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Indesit I6G52/UK 16 ページ。 Cooker and oven

Indesit I6G52/UK 取扱説明書

Table of burner and nozzle specifications

GB
Table 1
Burner
Diameter
(mm)
Fast
(Large)(R)
Semi Fast
(Medium)(S)
Auxiliary
(Small)(A)
Supply
Pressures
*
At 15°C and 1013 mbar- dry gas
**
Propane
***
Butane
Natural
S
S
R
A
I6G52/UK
6
Thermal Power
kW (p.c.s.*)
Nominal
Reduced
100
3.00
0.7
75
1.90
0.4
51
1.00
0.4
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
P.C.S. = 50,37 MJ/Kg
P.C.S. = 49,47 MJ/Kg
P.C.S. = 37,78 MJ/m
3
Liquid Gas
By-Pass
Nozzle
1/100
1/100
(mm)
(mm)
***
41
87
218
30
69
138
30
50
73
28-30
20
35
TABLE OF CHARACTERISTSICS
Dimensions
Volume
Useful
measurements
relating to the oven
compartment
Burners
Voltage and
frequency
ENERGY LABEL
Natural Gas
Flow*
Nozzle
g/h
1/100
**
(mm)
214
128
136
104
71
78
37
20
25
17
45
25
width 43,5 cm
height 32 cm
depth 40 cm
58 l
width 46 cm
height 8,5 cm
depth 42 cm
may be adapted for use with any type
of gas shown on the data plate, which
is located inside the flap or, after the
oven com partment has been opened,
on the left-hand wall inside the oven.
see data plate
Directive 2002/40/EC on the label of
electric ovens.
Standard EN 50304
Energy consumption for Forced
convection heating mode:
Fan assisted
Declared energy consumption for
Natural convection Class heating
mode:
Convection
This appliance conform s to the
following European Economic
Community directives: 2006/95/EC
dated 12/12/06 (Low Voltage) and
subsequent amendments –
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments - 93/68/EEC
dated 22/07/93 and subsequent
amendments.
2002/96/EC
2009/142/EC dated 30/11/09 (Gas)
1275/2008 (Stand-by/ Off mode)
Flow*
l/h
286
181
95