- ページ 19
オーブン Indesit KN6M40SA/TSのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Indesit KN6M40SA/TS 28 ページ。
Table of burner and nozzle specifications
Table 1
Burner
Diameter
(mm)
Rapid (Large)
100
(UR)
Semi-rapid
75
(Medium) (S)
Auxiliary
55
(Small) (A)
Supply
pressure
**
Propane P.C.S. = 50.37 MJ/kg
***
Butane P.C.S. = 49.47 MJ/kg
****
Natural P.C.S. = 37.78 MJ/m³
Pressed petroleum gas (LPG)
Nominal (mbar)
Required
Minimum (mbar)
pressure
Maximum (mbar)
S
S
UR
A
K6G40S / T
K6G40S / T
K6G40S / T
S S S
K6G40S / T
K6G40S / T
KN6G40SA / T
KN6G40SA / T
KN6G40SA / T
KN6G40SA / T
KN6G40SA / T
WARNING! The glass lid can break
in if it is heated up. Turn off all the
burners and the electric plates be-
fore closing the lid.
Thermal power
Bypass
kW (p.c.s.*)
Nominal
Reduced
3.30
0.70
1.90
0.40
1.00
0.40
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
Natural
Gas
37 **
28 ***
20 ****
25 **
20 * **
17 ****
45 **
35 ***
25 ****
ø 180
S
UR
A
K6M40S/ T
K6M40S/ T
K6M40S/ T
K6M40S/ T
K6M40S/ T
S S S
KN6M40SA/T
KN6M40SA/T
KN6M40SA/T
KN6M40SA/T
KN6M40SA/T
S S S
S S S
Liquid gas
Nozzle
Capacity*
1/100
1/100
g/h
(mm)
(mm)
***
41
91
240
30
70
138
30
50
73
28-30
20
35
TECHNICAL DATA
Oven dimensions
(LxDxH)
Volume
Useful
measurements
relating to the oven
compartment
Power supply
voltage and
frequency
Burners
ENERGY LABEL
0051
0051
0051
0051
0051
Data plate, is located inside the flap or, after the oven
compartment has been opened, on the left-hand wall
inside the oven.
Natural gas
Nozzle
Capacity*
1/100
l/h
(mm)
**
236
123
314
136
106
181
71
79
95
37
20
25
17
45
25
32x43,5x40 cm
62 l
width 42 cm
depth 46 cm
height 8,5 cm
see data plate
may be adapted for use with any type of
gas shown on the data plate
Directive 2002/40/EC on the label of
electric ovens. Standard EN 50304
Energy consumption for Forced
Fan
convection – heating mode:
Oven;
EC Directives: 06/95/EC dated 12/12/06
(Low Voltage) and subsequent
amendments –
04/108/EC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments –
93/68/EEC dated 22/07/93 and
subsequent amendments –
2002/96/EC.
1275/2008 Stand-by/ Off mode
GB
19