- ページ 7

ホブ Indesit PAA 642 IX/IのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Indesit PAA 642 IX/I 16 ページ。

Indesit PAA 642 IX/I 取扱説明書
IMPORTANT: should you experience difficulty in turning the burners
knobs, please contact the After Sales Service for the replacement of
the burner tap if found to be faulty.
• Adjusting the burners' primary air
Does not require adjusting.
• Setting the burners to minimum
1. Turn the tap to the low flame position;
2. Remove the knob and adjust the adjustment
screw, which is positioned in or next to the tap
pin, until the flame is small but steady.
3. Having adjusted the flame to the required low setting, while the burner is
alight, quickly change the position of the knob from minimum to maximum
and vice versa several times, checking that the flame does not go out.
4. Some appliances have a safety device (thermocouple) fitted. If the device
fails to work when the burners are set to the low flame setting, increase
this low flame setting using the adjusting screw.
5. Once the adjustment has been made, replace the seals on the by-passes
using sealing wax or a similar substance.
! Once this procedure is finished, replace the old rating sticker with one
indicating the new type of gas used. Stickers are available from any of our
Service Centres.
! Should the gas pressure used be different (or vary slightly) from the
recommended pressure, a suitable pressure regulator must be fitted to the
inlet pipe (in order to comply with current national regulations).
DATA PLATE
Electrical
see data plate
connections
ECODESIGN
This appliance conforms to the EU Regulation no. 66/2014
implementing Directive 2009/125/EC.
standard EN 30-2-1
GB
7