エアーコンプレッサー AC Tool Supply TA-3EAのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。AC Tool Supply TA-3EA 20 ページ。 For comp-3 & comp-3ea systems
The air filter is located beneath the filter cover (A). Disconnect pipe (B).
WARNING: IF ANY AIR ESCAPES BEFORE OUTLET PIPE IS FULLY REMOVED, STOP! DO NOT REMOVE
UNTIL ALL PRESSURE IS LOST.
1. Firmly pull cowl (A) to remove from air end.
2. Unclip air filter (D) from the retaining clip (F) and discard air filter.
Note: Air filter may contain traces of oil and must be disposed of in an approved manner.
3. Unclip air filter support (E) and clean separator casing and inside of cowl.
1. Remove cap head screws (G).
2. Gently tap the end cover (H) until it is clear of the separator casing.
3. Unscrew the oil separator element (J) and discard
4. Fit a new separator element (Model COMPA022). Ensure that the "O" ring (K) is in place. Do not overtighten.
5. Refit end cover (H). Ensure cover is positioned correctly and bolt holes are in line. Be careful not to damage
"O" ring (L) when refitting.
6. Refit cap head screws (G). Tighten between 4 - 6.8 Nm (3 - 5 ft/lbs).
1. Reinstall air filter support (E). Fit a new air filter (D) and secure both ends using the retaining clip (F).
2. Refit cowl (A).
3. Reconnect pipe (B) and tighten securely.