- ページ 9

換気フード AEG 835 DのPDF 据付・取扱説明書をオンラインで閲覧またはダウンロードできます。AEG 835 D 18 ページ。 Fume extractor hood

a chimney if the room and/or flat (air/environment combina-
tion) is ventilated from outside using a suitable ventilation
2
hole approximately 500-600 cm
large to avoid the possibility
of a depression being created during operation of the hood.
If you have any doubts, contact the relevant controlling
authority or building inspector's office.
Since the rule for rooms with fuel burning appliances is
"outlet hole of the same size as the ventilation hole", a hole
2
of 500-600 cm
, which is to say a larger hole, could reduce
the performance of the extractor hood.
If the hood is used in its filtering function, it will operate
simply and safely in the above conditions without the need
for any of the aforementioned measures.
When the hood is used in its extractor function, the following
rules must be followed to obtain optimal operation:
— short and straight outlet hose
— keep bends in outlet hose to a minimum
— never install the hoses with an acute angle, they must
always follow a gentle curve only
— keep the hose as large as possible (150 mm Ø min.).
Failure to observe these basic rules will drastically reduce the
performance and increase the noise levels of the extractor
hood.
25