- ページ 3

換気フード AEG 8609 DのPDF 取付・使用説明書をオンラインで閲覧またはダウンロードできます。AEG 8609 D 24 ページ。 Build-in chimney fume extractor hood
AEG 8609 D にも: 取付・使用説明書 (24 ページ), 取扱説明書 (28 ページ), 取扱説明書 (28 ページ)

For the
electrical
installer
For the kitchen
. furniture
installer
28
Safety instructions
Arrangement of the protective contact plug socket inside the
chimney cover plate (Fig. EO/2) confers two advantages:
1. The plug socket is not visible.
2. You can easily de-energize the appliance where necessary
by unplugging it.
For the necessary fixed connection, the fume extractor hood
may be connected only by an electrical installer registered with
the electricity board covering your area. An isolating device is to `
be provided on the fixed wiring side.
Switches with a contact opening of more than 3 mm also apply
as isolating devices. These
include line protection switches,
fuses, and contactors (VDE 0730, s. 7, Part 1).
Connection
220 V~ via fixed supply lead with protective contact plug (Eu-
ropa version).
240 V~ via fixed supply lead (UK).
(Fixed connection to be made only by an approved electrical `
installer)
This appliance complies with the radio interference suppression
requirements of EC Directives 76/889 EC and 82/499 EC.
The exhaust air may not be introduced into a smoke flue or
exhaust gas chimney.
|. Introduction of the exhaust air into a shaft bad for ventilation
of the installation spaces of firerooms is not permitted.
If the exhaust air is introduced into a non-operational smoke
fiue or exhaust gas chimney, it is advisable to seek the con-
sent of the competent chimney-sweep.
The official exhaust air guidance regulations are basically to
be complied with.
During operation as an exhaust air appliance, an adequate
supply air opening of approximately the same size as the ex-
haust air opening is to be ensured.
According to the Provinciai Building Regulations, the joint op-
eration
of fume
extractor
hoods
and chimney-linked
fire-
places, such as coal- or oil-fired ovens and gas heaters, in the
same space is subject to specific restrictions.
In such spaces, the Fireplace Regulations only allow an under-
pressure of max. 0.04 mbar.
The safe joint operation of chimney-linked
appliances
and
fume
extractor
hoods
is only guaranteed
if space
and/or
dwelling (space/air interaction) are externally ventilated by a
suitable supply air opening of around 500—600 cm? and an
underpressure thereby avoided when the fume extractor hood
is running.
SIE2
5/80
— SIKM1
14/89
GB/EU