- ページ 3
配管製品 Kohler TROCADERO K-2249のPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Kohler TROCADERO K-2249 8 ページ。 Fireclay pedestal lavatory
3. INSTALLATION
A. PREPARATION
1.
Rough-in hot/cold water supplies and drain piping.
Refer to Fig. #1 .
NOTE: The trap must be installed so centerline of
lavatory outlet is 7-1/2" from finished wall.
NOTE: Supply stop handles (fully opened) must not
extend beyond 4" from finished wall to avoid
interference with back of pedestal.
2.
Install sufficient bracing behind finished wall to support
150 pounds.
3.
Mark location of lavatory hanger bolts and install the
hanger bolts. They should protrude 1-3/4" from finished
wall.
NOTE: Ensure each hanger bolt height from floor is
exact by using a level, or lavatory will not be level when
installed.
B. INSTALL FITTINGS
1.
Install faucet and drain on lavatory. Use product
manufacturer's instructions. Ensure 1-1/4" tailpiece is
installed in drain body.
C. INSTALL LAVATORY
NOTE: Three people are required for lavatory
installation: two people to support lavatory and one to
guide and attach hardware.
1.
Carefully slide lavatory onto hanger bolts. Ensure
lavatory is level and drain is properly aligned. Adjust as
required.
2.
Secure lavatory to wall with rubber washers, metal
washers and nuts. Do not overtighten nuts.
CAUTION: Risk of personal injury or product
damage. Fireclay lavatory can chip or break easily
if bolts or nuts are overtightened or product is
handled carelessly.
Kohler Co., Kohler, WI
Finished Wall
31-1/4"
To Floor
Hanger Bolts
Rubber Washer
Metal Washer
3
Wall Bracing
11"
Hanger Bolts
Fig. #2
Nut
Fig. #3
BB