Troubleshooting (cont.)
Symptoms
5. Waterfall lights do not
work.
6. Unit stops automatically
before 18 minutes.
7. Unit does not stop
automatically after 22
minutes.
8.
Noisy operation.
9.
Remote does not work.
Kohler Co.
Probable Causes
B. Waterfall wiring loose/damaged
or butterfly valve is faulty.
C. Not enough water in footbath
basin (pump cavitates).
D. Keypad does not work.
E. Control does not work.
A. Loose or damaged wiring.
B. Power supply for lighting does
not work.
A. GFCI or RCD has tripped.
B. Motor overheated and protection
device activated.
A. Timer mechanism accidentally
deactivated.
A. Not enough water in footbath
basin.
B. Band straps (if applicable) on the
pump are not cut.
A. Remote not programmed.
11
Recommended Action
B. Identify source of fault and
correct or replace wiring or
butterfly valve. Refer to
installer/dealer.
C. Fill basin 3" (7.6 cm) over top of
suction cover.
D. Replace keypad. Refer to
installer/dealer.
E. Replace control. Refer to
installer/dealer.
A. Identify source and correct. Refer
to installer/dealer.
B. Replace lighting supply box in
tower. Refer to installer/dealer.
A. Set/Reset GFCI or RCD.
B. Check for restricted air space
around pump box, motor vent
blockage, suction/harness
blockage. Correct and allow
motor to cool.
A. See Service Manual. Refer to
installer/dealer.
A. Fill basin 3" (7.6 cm) over top of
suction cover.
B. Cut band straps.
A. Re-program remote following
instructions.
1030200-5-B