Before You Begin (cont.)
Before installation, provide access at the back of the plumbing wall. Because the module is
one-piece, the drain and overflow connections cannot be made by reaching over the end of the
module.
Make sure the installation area is clean and free of all debris. If remodeling, remove all finished wall
material to expose the framing and remove all floor coverings to expose the subfloor.
Consult all applicable instructions for options and accessories before beginning this installation.
Fixture conforms to ANSI Standard Z124.2. All dimensions are nominal.
Kohler Co. reserves the right to make revisions in the design of products without notice, as specified
in the Price Book.
Roughing-In Provisions
IMPORTANT! All dimensions are nominal. The stud opening tolerance is +1/4" (6 mm)/-0. Carefully
measure your fixture before determining enclosure size. Some shimming between the stud frame and the
fixture may be required. If a firewall is required, rough-in dimensions will have to increase according to
the thickness of the firewall material. Stud opening dimensions must be measured toward the exposed
side of the wall material. When a fire-rated wall is specified, dimensions are to the inside of the wall
board. Dimensions given in the rough-in information are crucial for proper installation. Construct the
framing and plumbing accurately.
NOTE: The basin area requires no additional support when the subfloor is level and square with respect to
the framing. Consider using shims for additional support if the subfloor is uneven.
ADA Provisions
These models comply with the Americans with Disabilities Act when installed per the requirements
of the Accessibility Guidelines, Section 4.21 Shower Stalls, of the Act. Consider the user's physical
limitations when determining the position of the module and the location of the shower control
area(s). To ensure ADA compliance, position the module exactly as shown in the roughing-in
diagram. Locate the shower control areas as illustrated.
Provide clear floor space according to the roughing-in illustrations. You can provide the clear floor
space with either a front or side user access. Consider the path of the wheelchair user when
building the clear floor space. Be sure there is sufficient room for a wheelchair user to enter the
room and maneuver the wheelchair to the module.
When possible, a side entrance to the module should be employed to ensure the easiest wheelchair
accessibility.
If the user will have caregiver assistance, we recommend using a front entrance.