BEFORE INSTALLING UNIT
BEFORE INSTALLING UNIT
A. The following installation practices
must be followed
damage to the enamel finish.
WARNING: Failure to follow the manufacturer's
recommended installation method may result in
damage to the enamel surface.
·
Do not use sharp objects or metal tools when
handling the bath, especially around the rim area.
·
Use a clear protective plastic film over tub rim as
well as the bottom of tub to safeguard from dirt and
silicone during the installation process.
·
For correct installation, bath rim should not come in
direct contact with the walls and/or horizontal
surfaces to avoid transmission of noise and vibration
as well as potential cracks in the enamel finish.
·
The necessary gap between bath rim and the wall is
2 mm horizontally and 4 mm vertically. Refer to
figures 1, 2, and 3 below.
·
Before placing setting-in the bath, apply a sanitary
quality silicone filler on all surfaces to come in
contact with the bath rim.
!
Set the bath in its correct position.
UNIT: mm
:
silicone filler
tiling
B. Partially Install Bath Drain
Install the drain on the bath according to the drain
manufactuer's instructions.
1046553-T01-B
to avoid any potential
bath
4
wall
1
A
.
·
·
·
·
·
·
silicone filler
4
tiling
2
B.
4
1
2
3
bath
wall
wall
2
4
2
bath
4
silicone filler
3