Screen Four: SET THRESHOLD TOTAL 2 (factory set at 80)
Set this option for the total amount of gallons required to deliver a
service call alert to the customer
Set threshold gallons (x1000)
Recommended setting for 9x48 system is 80; 10x54 system is120
Yellow light blinks at 80% threshold
Red light blinks at 90% threshold
Alarm beeps at 100% threshold
Opt2 connection is powered with 12 VAC at 100% threshold
(30 milliamps (mA) max.)
Press the Flow button to advance to next screen
Screen Five: SET GAL/MIN (no factory setting)
This function is primarily for an external device, i.e. a secondary pump,
chemical feed or auxiliary signal, etc
Set GPM for the 20 mA output flow rate
Zero flow is a fixed 4 mA output
Verify polarity 4-20 mA output at J2 connection
4-20 mA proportional flow rate output
Press the Flow button to advance to next screen
Screen Six: SET GAL 1 (factory set at 20)
This setting fixes the number of gallons before auto pump starts
Set the gallon batch to energize Opt1 connection
Set at 10 gallons
For Air Pump factory setting is 20 gal
Feed Pump setting is 1 gal. for 10 GPM peak flow; 2 gal. for 20 GPM
peak flow; 3 gal. for 30 GPM peak flow; 4 gal. for 40 GPM peak flow
A setting of zero energizes Opt1 like a flow switch, sensitive at .5 GPM
Press the Flow button to advance to next screen
Screen Seven: SET MIN 1
This setting factors the run time duration of the auto air pump or
feed pump after water usage has discontinued (.1 would be 6 seconds.)
Set delay off in minutes for Air Pump - Opt1 connection
Set between 0.1 and 90 minutes.
Air Pump setting is .33min
Feed pump setting is 0.10 min.
Opt1 is 12 VAC (30 mA max.)
Press the Flow button to advance to next screen
*Please contact your water professional to confirm the proper settings for your application. The above values are recommendations
only.