- ページ 6

エンジン Kohler Command PRO CH740のPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Kohler Command PRO CH740 12 ページ。 Liquefi ed petroleum gas (lpg) or lpg/natural gas (ng) fueled
Kohler Command PRO CH740 にも: オーナーズマニュアル (21 ページ), オーナーズマニュアル (21 ページ), オーナーズマニュアル (8 ページ), オーナーズマニュアル (21 ページ), オーナーズマニュアル (21 ページ), オーナーズマニュアル (24 ページ), オーナーズマニュアル (10 ページ), オーナーズマニュアル (8 ページ)

Kohler Command PRO CH740 オーナーズマニュアル
Oil Recommendations
Synthetic oil is recommended for use in
LPG/NG fueled engines. Non-synthetic oil must
be low ash* rated oil. Oils (including synthetic)
must meet API (American Petroleum Institute)
service class SG, SH, SJ, or SL. Select
viscosity based on air temperature at time of
operation as shown in table below.
*Low ash is defi ned as less than 1% sulfated
ash.
5W-30
°F -20
0
20
°C -30
-20
-10
Check Oil Level
NOTE: To prevent extensive engine wear or
damage, never run engine with oil level
below or above operating range
indicator on dipstick.
Ensure engine is cool. Clean oil fi ll/dipstick
areas of any debris.
1. Remove dipstick; wipe oil off .
a. Press-in cap: reinsert dipstick into tube;
press completely down.
b. Thread-on cap: reinsert dipstick into
tube; rest cap on tube, do not thread cap
onto tube.
2. Remove dipstick; check oil level. Level
should be at top of indicator on dipstick.
3. If oil is low on indicator, add oil up to top of
indicator mark.
4. Reinstall dipstick and tighten securely.
6
10W-30
SAE 30
32
40
50
60
80
0
10
20
30
or
KohlerEngines.com
Change Oil and Filter
Change oil while engine is warm.
1. Clean area around oil fi ll cap/dipstick, drain
plug/oil drain valve.
a. Remove drain plug and oil fi ll cap/
dipstick. Allow oil to drain completely.
b. Open oil drain valve cap; if needed,
attach a length of 1/2 in. I.D. hose to
direct oil into appropriate container; twist
valve drain body counterclockwise and
pull. Remove dipstick. Allow oil to drain
completely.
2. Clean area around oil fi lter. Place a container
under fi lter to catch any oil and remove fi lter.
Wipe off mounting surface.
100
a. Reinstall drain plug. Torque to 10 ft. lb.
40
(13.6 N·m).
b. Close oil drain valve body, remove hose
(if used), and replace cap.
3. Place new fi lter in shallow pan with open end
up. Fill with new oil until oil reaches bottom of
threads. Allow 2 minutes for oil to be
absorbed by fi lter material.
4. Apply a thin fi lm of clean oil to rubber gasket
on new fi lter.
5. Refer to instructions on oil fi lter for proper
installation.
6. Fill crankcase with new oil. Level should be
at top of indicator on dipstick.
7. Reinstall oil fi ll cap/dipstick and tighten
securely.
8. Start engine; check for oil leaks. Stop engine;
correct leaks. Recheck oil level.
9. Dispose of used oil and fi lter in accordance
with local ordinances.
or
or
24 590 48 Rev. --