- ページ 5

エンジン Kohler command pro PCH740のPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Kohler command pro PCH740 12 ページ。 Propane electronic fuel injection efi
Kohler command pro PCH740 にも: オーナーズマニュアル (12 ページ)

Kohler command pro PCH740 オーナーズマニュアル
Maintenance Instructions
Accidental Starts can cause
severe injury or death.
Disconnect and ground spark
plug lead(s) before servicing.
Normal maintenance, replacement or repair of emission control devices and systems may be
performed by any repair establishment or individual; however, warranty repairs must be performed
by a Kohler authorized dealer found at KohlerEngines.com or 1-800-544-2444 (U.S. and Canada).
For safety and health reasons, many states require special licensing or certifi cation for servicing
propane fuel systems. Check local and state regulations before choosing a repair establishment to
perform fuel system repairs.
Maintenance Schedule
Every 25 Hours
1
● Service/replace low-profi le precleaner (if equipped).
Every 100 Hours
1
● Check oil cooler fi ns, clean as necessary (if equipped).
● Change oil.
● Replace low-profi le air cleaner element (if equipped).
● Remove cooling shrouds and clean cooling areas.
Every 150 Hours
1
● Check heavy-duty fi lter minder.
● Inspect heavy-duty air fi lter paper element and inlet screen area.
Every 200 Hours
1
● Change oil fi lter.
● Replace unique EFI fuel fi lters.
Every 300 Hours
1
● Replace heavy-duty air cleaner element and check inner element.
Every 500 Hours or Annually
● Check all lines (high pressure/vacuum) including fi ttings for leaks.
● Drain vaporizer/regulator of accumulated fuel deposits.
● Replace spark plugs and set gap.
Every 500 Hours or Annually
● Inspect lock-off assembly for damage/leakage.
● Have combustion deposits removed if using non-synthetic oil.
Every 600 Hours or Annually
● Replace heavy-duty air cleaner inner element.
Every 1500 Hours
1,2
● Have vaporizer/regulator tested.
Perform these procedures more frequently under severe, dusty, dirty conditions.
1
Must be performed by a Kohler authorized dealer or qualifi ed propane personnel only.
2
24 590 52 Rev. --
WARNING
1
1,2
1
KohlerEngines.com
Before working on engine or equipment, disable
engine as follows: 1) Disconnect spark plug
lead(s). 2) Disconnect negative (–) battery cable
from battery.
5