Basic Use without SmartCOM Server
 Insert the SIM card that supports data with a
public IP address (fixed or dynamic) and PIN
request disable or the same PIN as requested
®
in the 2N
SmartCOM configuration.
 Connect the antenna and then the power
supply.
 Get connected via serial port (115200 baud,
8N1, no flow control) to identify the IP
address assigned to 2N
configure basic settings if necessary.
 Upon power up, the port is in the data mode
and retransmits everything from the GSM
input. Use sequence +++ to switch into the
command mode.
 Now you can configure 2N
using the AT commands listed below.
 Restart the port (at^scport1="restart") to return
to the data mode (also possible with ATO
command).
 Connect the device to one of the available serial
ports (RS232 or RS485).
 Start a telnet application (e.g. Putty) and get
connected to the public IP address of
®
2N
SmartCOM via TCP port 10000 to set
parameters as via a serial port.
 Use TCP port 10001 for data retransmitting
to RS232.
 Use TCP port 10002 for data retransmitting
to RS485.
Basic AT Commands
Global
ati3 – fw versions
ati4 – serial number
at^scupg="http://../file.bin" – upgrade
ate0 – echo disable
ate1 – echo enable
at^scfres – factory reset
Module
at+cgsn – module IMEI
at+cimi – SIM card IMSI
at+csq – GSM module status
Configuration
at^sccfg? – current GSM settings
at^sccfg=? – GSM setting options
at^scport1? – RS232 setting
Examples
1) at^sccfg="gprs_apn","internet.open" //change APN
2) at^sccfg="srestart" //save and restart
3) at^sccfg? //read current setting (IP address)
Declaration of Conformity
2N TELEKOMUNIKACE a.s. hereby declares that the 2N
requirements and other relevant provisions of the 1999/5/EC directive. For the full wording of the
Declaration of Conformity see www.2n.cz.
®
SmartCOM or
®
SmartCOM
Use with SmartCOM Server
 The
server
receives
terminals providing central administration.
 Refer to the User Manual for details on the 2N
SmartCOM server settings, management and
use.
Input and Output Circuits
®
 2N
SmartCOM is equipped with two serial
interfaces, which are electrically interconnected
with the GND reference point.
 The input may be current (0-20mA, 4-20mA,
100Ω input impedance), and voltage (0-10V
DC, 100MΩ input impedance) controlled or S0.
Use the jumpers inside 2N
the current and voltage modes.
®
 2N
SmartCOM is equipped with two relay
outputs
for
switching
appliances. Refer to the Technical Parameters
in the User Manual for the maximum switching
values.
at^scport1=? – RS232 setting options
at^scport2? – RS485 setting
at^scport2=? – RS485 setting options
at^xxx="save" – module configuration saving
at^xxx="restart" – module restart (xxx=e.g. sccfg)
at^xxx="srestart" – save to module and restart
Inputs and Outputs
(#...number in range 1 - 2)
at^screl#? – relay # status
at^screl#=0 – relay # opening
at^screl#=1 – relay # closing
at^scadc#? – analogue input # status and limits
at^scadc#=? – analogue input # parameters
at^scdin#? – digital input # status and limits
at^scdin#=? – digital input # parameters
4) at^scport1=" baudrate",57600 // RS232 baudrate
5) at^scport1="srestart" //save and restart
6) ato // switch to data mode on RS232
®
SmartCOM product complies with all basic
registrations
from
®
®
SmartCOM to set
ON/OFF
electrical