室内装飾品 Kohler K-45775TのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。Kohler K-45775T 8 ページ。 Bristol series bathroom cabinets
b. Floor drainage (S-Trap)
Please install the drain assembly and faucet as shown.
Please set the water supply and drainage position
according to the suppliers instructions. You can adjust the
height of shelf to fit the drain assembly.
Note: For installation of 1600mm cabinet, if the drainage
hole is in the middle of the cabinet, please first remove the
middle drawer and reinstall it onto the rail after fixing the
drainage.
5. Run water into the washbasin or vanity top, and check the
drain connections for any leaks.
6. Adjust all doors and drawers in three-way as illustrated in
Fig 8, and make sure that the door is level and neat.
Clearance between doors is even, and that between doors
and cabinet is tight.
7. Install the decorative cover and buffer.
1202483-T01-B
Door
Fig.14
14
b.
S
Drain Assembly
Back Board
Outlet
1600mm
5.
6.
7.
-7-
Faucet
Supply Lines
Shut-off Valve