- ページ 10
体重計 acaia PyxisのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。acaia Pyxis 15 ページ。
acaia Pyxis にも: ユーザーマニュアル (15 ページ), ユーザーマニュアル (15 ページ)
Dual Display Mode Setting [ NOdE_2 ]
1. The Dual Display Mode is set to On by default.
• On: The Dual Display Mode is enabled.
• Off: The Dual Display Mode is disabled.
Auto Start Mode Setting [ NOdE_3 ]
1. The Auto Start Mode is set to On by default.
• On: The Auto Start Mode is enabled.
• Off: The Auto Start Mode is disabled.
Bluetooth Setup Setting [ bt_SEt ]
1. Off: Bluetooth is disabled. The scale does not allow any Bluetooth connection.
2. On: Bluetooth is enabled. The scale allows Bluetooth connection. The user may connect the
scale with Acaia apps.
Battery Saving [ bAttSA E ]
1. The Acaia Pyxis will wait for the selected number of seconds to enter Battery Saving. The LED
display will dim to save power.
2. The default length of time before entering Battery Saving is 90 seconds.
Auto Start Sensitivity [ SEnSE ]
1. Minimum weight is decreased for more sensitivity. This is ideal for slower espresso shots in the
droplet icon modes. Stability depends on environmental noise.
2. The number indicates the sensitivity of flow detection in the droplet icon modes. Smaller value
indicates higher sensitivity, but is recommended only for stable working environments.
3. Tap the Tare button to toggle through the options.
Auto Reset [ Auto_rES ]
1. After a cup is removed, the timer will automatically reset. This setting gives you options on how
long to wait before resetting. It enables the user to pull successive shots of espresso quickly in
the three auto-start modes.
2. The number indicates the timeout value of timer reset after a cup is removed.
3. Tap the Tare button to toggle through the options.
Reset to Default Setting [ rESEt d ]
1. Select [ YES ] to set all settings to default value.
v
.
10