Use fittings with cylindrical thread with GAS
or BSP pitch. Do not use fittings with
tapered threads.
When fixing the fittings to the head, avoid
using sealing pastes, hardening liquids,
silicone, hemp or other, but only Teflon
tape.
After fixing, open the taps and check that
there are no leaks or drips.
STARTING AND OPERATION OF
THE FILTER
After fixing and connecting the filter to the
water mains, you can start using it.
The first operation is to insert the
cartridge inside the filter.
After closing the water, open the filter
using the special key and insert the filter
cartridge necessary for the chosen
treatment inside it.
CAUTION: Remove the film or package
that wraps the cartridge. If the cartridge
has gaskets, make sure they are
correctly positioned before closing the
sump.
After placing the cartridge in the sump,
put the O-Ring in its seat and screw the
sump clockwise onto the head.
It is recommended to tighten tightly, but by hand (without using the key). If, once put into operation,
drips occur, tighten further with the aid of the key.
Re-open the water, check that there are no drips and vent the vessel by slightly opening the vent
screw on the head (or by pressing the appropriate button if present).
Let the water flow from a tap for a few minutes, in order to evacuate all the air and remove any dust
or dirt present in the filter, even after its assembly.
After these operations the filter is running regularly.
These operations must be repeated every time the filter cartridge is replaced or serviced.

CLEANING AND MAINTENANCE

ATTENTION: This equipment requires regular periodic maintenance in order to ensure the potability
requirements of the treated drinking water and the maintenance of improvements as declared by the
manufacturer.