- ページ 2
室内装飾品 AvLab AP4-0085AのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。AvLab AP4-0085A 2 ページ。 Electric dual motor sit-stand desk frame corner
INSTALLATION
3
Fix the frame 1 (7) with screws (B)
Fix the frame 2 (11) with screws (D)
Secure the side plate (1) with screws (D)
D
M6x35 SCREW 6PCS
B
M6x12 SCREW
2PCS
E
S=4mm
7 Frame(1)
1PCS
Insert the connecting rod (3) into the frame
4
Adjust the distance according to the size of the table,
and then tighten the screw (B) with the wrench (E).
B
M6x12 SCREW
16PCS
B
M6x12
E
5
Mount the desktop (13) with screws (A) on the two side plates
E
A
S=4mm
M5x16 SCREW
13PCS
1
Mount the control box (8) under desktop(13) with screws (A).
6
11 Frame(2)
Use the screws (A) to install the controller panel(12) under
1PCS
the desktop. Connect two table boards with the table board
connection board (10).
M5x16 SCREW
2PCS
3 Connecting line 4PCS
7
A
M5x16 SCREW
2PCS
A
M5x16 SCREW
8PCS
10 Table board
A
connection board
8 Connecting rod
2PCS
OPERATION
13
Press
and display real height
Press
and display real height
Press
until 1 appears, release the button, it runs
to corresponding height and displays current position.
Press
until 2 appears, release the button, it runs
to corresponding height and displays current position.
Press
until 3 appears, release the button, it runs
to corresponding height and displays current position.
Press
until 4 appears, release the button, it runs
to corresponding height and displays current position.
Save button,used to enter the save height function
After
press , the interface flashes and set memory
M
Memory
position, press
Position
it displays current height.
in condition of E2 or run to basic height position, long
press
for 5 seconds, display RES and press still, it
Reset
goes down to the lowest and rebound certain height,
reset finish and show basic height.
Protection mode (auto lock screen mode)
Over-heating
Hot: it alarms when continuous working 2 minutes;
protection
clear automatically after resting 18 minutes.
Sensorless
E1: It alarms when motor hall value cannot be inspected;
alarm
clear it after press reset or re-power on.
E2: overload alarm when running up, clear automatically
Overload
after 3 seconds; overload alarm when running down,
protection
clear it after press reset or re-power on.
E02: it alarms in reversed compression when running;
Rebound
clear automatically after rebound 4cm; or press any
protection
button to clear when rebounding.
Overvoltage
E03: it alarms when voltage is higher than limit value,
alarm
clear automatically after voltage reduced to set value.
Undervoltage
E05: it alarms when voltage is lower than limit value;
alarm
clear automatically after voltage is higher than set value.
E06: it alarms when height difference between left and
Step out alarm
right leg exceeds the set value; clear it after re-power on.
It stops and enters protection state when motor lines or
Breaking
manual control lines are removed or disconnected
protection
accidentally; back to normal after reconnected and alarm
cleared.
Press
M
for 3 seconds and it will display ---, release
press
until 0 appears, release the button and it
Metric and
displays current height. (metric unit)
English
Press
for 3 seconds and it will display ---, release
unit conversion
M
press
until 1 appears, release the button and it
displays current height. (English unit)
until H1 appears, release button and
M
,
,
M