condenser.
5.
At the rear of the unit, locate the water connection fitting with a coil of tubing next to the condenser.
When using a Filter system, disconnect the Elbow (In-line) fitting at the mid length of the tube, and
store for future use with the Bottled water feature. (Fig. C)
6.
Assemble the filter as per individual instructions.
noTe: filter set sold separately.
7.
The filter bracket has several hole patterns to accommodate different filter mounting configurations. It
may be necessary to provide your own holes per your individual filter instructions.
noTe: mounting screws are not included with your cooler.
8.
Mount the filters to the filter bracket per individual instructions. (Fig. D)
NOTE: Follow any preflush instructions supplied with your filter set before making any
connections to the water cooler.
9.
Connect the water supply tube to the inlet side of the connection fitting, at the rear of the cooler.
And, connect the length of 1/4" tubing from the connection fitting (on the inside of the cooler) to your
filter system. (Fig. E)
10.
Connect the 1/4" tube, leading to the water valve (supplied with your cooler) to the outlet side of
your filter system. (Fig. F)
11.
Make your external water supply connections.
NOTE: Observe all local and state plumbing codes.
12.
Your cooler is equipped with an open-door interlock system that will suspend all cooler functions while
the access door is open. The access door must be shut for the cooler to operate correctly. (Fig. G)
NOTE: Follow start-up instructions at the front of this document.