To ensure you install the unit easily and correctly, PLEASE READ THE FOLLOWING
INSTRUCTIONS BEFORE STARTING INSTALLATION. CHECK YOUR
INSTALLATION IS IN COMPLIANCE WITH PLUMBING, ELECTRICAL AND
OTHER APPLICABLE CODES. There are some simple diagrams to assist you in the
installation of the cooler on the last sheet of this booklet. After installation, leave these
instructions inside the cooler for future reference.
IMPORTANT INFORMATION ABOUT YOUR WATER COOLER
1. The water cooler is not intended for outdoor use.
2. All service work to be carried out by authorised Aqua Cooler service agents only.
Failure to do so will void the warranty on the water cooler.
3. Warranty will also be voided if installation is not carried out as detailed in the Aqua
Cooler installation instructions.
4. The thermostat is pre-set and non-adjustable for 10 degree water under normal
conditions.
5. The coolers are tested to meet accreditation standards. This cooler meets the
AS/NZS 1044:1995 EMC testing standards for electrical interference. They meet
the TYPE test MP52 plumbing standards for back flow prevention and they are
tested to meet IEC 60 335-2-24:97 plus amendments for electrical safety.
If you would like Aqua Cooler to install the system for you, please contact us at the
number on the cover of this booklet.
1. Ensure proper ventilation by allowing 75mm clearance on each side of the cooler.
2. Minimum water pressure is 100 kpa and maximum is 700 kpa. If the water pressure
exceeds 700 kpa a pressure limiting valve should be fitted. These are an optional
extra and are available through Aqua Cooler, if needed.
3. Install a 40 mm waste trap onto the waste outlet on the rear of the cooler - not
supplied.
4. Water in connection is secured via a ½" kinko nut and olive into the stainless
connection on the rear of the unit as per the diagram in this booklet. It is
recommended that a ½" shut off valve is installed at this point for the purposes of
future maintenance.
5. Turn on water supply and hold down bubbler and purge system of air until a steady
stream of water comes from the tap.
6. The tap needs to be adjusted for the correct water flow in relation to the local water
pressure. On the side of the tap is an inner and an outer screw. Once you have
established a steady water flow adjust the INNER screw until the stream is in the
centre of the stainless steel top.
7. Check all connections for water leaks.
8. Plug the cooler into the building electrical supply. The unit will start automatically.
INSTALLATION INSTRUCTIONS
FOR THE INSTALLER
INSTALLATION