水システム Aqua Cooler AC-MW8EBFY-ASMのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Aqua Cooler AC-MW8EBFY-ASM 8 ページ。 Wall-recessed bottle filler

INSTALLATION CONT.
STEP 4 - FINAL ASSEMBLY
Install upper front panel assembly using screws provided
Install lower front panel using screws or locks provided
TRIM BEZEL - INSTALLATION
Install frame assembly to a flat surface, use appropriate fastening hardware (not included), refer
to rough-in for correct installation height.
Remove bottom plate from trim bezel (4 screws)
Install trim bezel to frame assembly and replace bottom plate with 4 screws.
Your Partner in Cool.
8
SET-UP GUIDES CONT.
BOTTLE FILLER ELECTRONICS:
Factory default program settings:
• Units: Gallons
• Unfiltered unit
• Flow meter = Rate selected
• Filter capacity = 1250 gallons (4731L) for VersaFilter
• Bottle count = 0.5L (1 bottle)
• Flow rate = 1.2 GPM
• 20s max dispense time.
To change the program settings, follow these steps:
DISPLAY
ACTION
000000000 BOTTLES
Depress button for 3 seconds to enter into the following menu settings and make changes.
REUSED
Note: at anytime it will exit menu and save settings when idle for 10 seconds (no button press) and
(Home Screen)
revert back to Home Screen.
LTR/GAL
Depress button for 3 seconds to change from Gallons to Litres, or momentary press to advance to
GAL
next menu.
UNFILT/FILT?
Depress button for 3 seconds to change from Unfiltered to Filtered unit, or momentary press to
UNFILT UNIT
advance to next menu
FLOW METER?
Depress button for 3 seconds to change from Rate Selected to (Flow) Meter Enabled, or
RATE SELECTED
momentary press to advance to next menu
SELECT RATE
To change flow rate, momentarily depress button to change whole gallon digit.
1.2 GPM UNIT
Hold button 3 seconds to advance to TENTHS of gallon digit.
Depress momentarily to change the digit.
Hold button 3 seconds to advance to the next menu.
RESET 000000000
Depress button for 3 seconds to reset Gallon or Litre count, or momentary press to advance to
GALLON CNT
next menu
[LTR COUNT]
FILT CAPAC
Depress button for 3 seconds to change filter capacity to 3000 GAL [11355 Litres] for Versafiller I
OF 1250 GAL
or Galaxi green filter, or momentary press to advance to next menu
[4731 LTR]
3 sec rule?
Depress button for 3 seconds to switch from 0.5L bottle to 3 sec rule, or momentary press to
0.5L
advance to next menu. (The 3 Sec rule increases the bottle count based on a 3 second dispense.)
RESET 00000000
Depress button for 3 seconds to reset (Home Screen) BOTTLES REUSED count, or momentary
BOT COUNT?
press to advance to next menu.
Bot Filler
Depress button for 3 seconds to change maximum dispense time to 10, 20, or 30 seconds, or
Set_time:20s
momentary press advance to next menu.
RUN CAL
Depress button for 3 seconds to run calibration again, or momentary press to advance to next
AGAIN?
menu.
REMOVING FROM SERVICE
• Disconnect the power supply.
• Disconnect the water supply.
• Drain cooler by removing grille, closing supply valve, and draining water.
• Remove the drain plug and bubbler.