Put dryer in PROGRAM mode as instructed on page 9. The dryer remains in the PROGRAM mode until one of these
actions occur:
• The switch is actuated again.
• The seventeenth step is completed and the START switch is pushed following the seventeenth step.
• Programming is stopped for about a minute.
• The loading door is closed.
Observe the displayed value in each step. If no change is required, press START to advance to the next program
step. If a change is required the values are made larger by the HOT or HIGH button, smaller by the MED button. The
hour meter and money audit can be reset to zero if WARM or LOW is pressed.
Note that after any reset or program change it is necessary to advance to the next step by pressing START to enter
the revision. OTHERWISE THE VALUE WILL REMAIN AS IT WAS BEFORE THE ALTERATION.
SERVICING DRYER
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.
ATTENTION. Lors des opérations d'entretien des commandes, étiqueter tous les fils avant de les déconnecter.
Toute erreur de câblage peut être une source de danger et de panne.
DAILY
1. Clean lint screen. Use soft brush if necessary.
2. Check lint screen for tears. Replace if necessary.
3. Clean lint from lint screen compartment.
MONTHLY
1. Remove lint accumulation from end bells of motor.
2. Remove lint from meter compartment and meter mechanism.
3. Remove lint and dirt accumulation from top of the dryer and all areas above, below and around the burners and
burner housing. Failure to keep this portion of the dryer clean can lead to a build-up of lint creating a fire hazard.
4. Place a few drops of light oil on clothes door hinge.
5. Grease bearings and shaft of intermediate drive pulley. Use Alemite gun and grease No. BRS-2 Molycote.
QUARTERLY
1. Check belts for looseness, wear or fraying.
2. Inspect gasket of door glass for excessive wear.
3. Check tightness of all fasteners holding parts to support channel.
4. Check tightness of all set screws.
5. Inspect impeller for tightness of blades to hub.
6. Check tightness of tumbler shaft retaining nut.
7. Remove back inspection plate and check tumbler thru-bolts for tightness.
8. Remove lint accumulation from primary air ports in burners.
9. Grease pivot pins and tension arms where in contact with each other.
SEMI-ANNUALLY
1. Remove and clean main burners.
2. Remove all orifices and examine for dirt and hole obstruction.
3. Remove all lint accumulation. Remove front panel, lint screen housing and remove lint accumulation.
ANNUALLY
1. Check intermediate pulley bearings for wear.
2. Check and remove any lint accumulation from exhaust system.
CHANGING PROGRAM DATA
PREVENTIVE MAINTENANCE INSTRUCTIONS