Symptom
TEMP SENSOR
SHORT
TEMP SENSOR
OPEN
PCB ERROR1
PCB ERROR2
COMM ERROR1
COMM ERROR2
COMM ERROR7
Fuse Error
4
Part # 8533-076-001 11/13
Dryer Error Codes
Probable Cause
Shorted Temperature
Sensor or wire.
Open Temperature
Sensor or wire
Memory corrupted
Analog/ Digital Error
Communication Bus
Error
No Dryer Model Selected This error occurs when a pin combination
Communication Bus
Error
Internal Control program
Error.
Suggested Remedy
The dryer control shall not start until
the detected short circuit is removed.
Regardless of condition of short circuit,
Error Code will be displayed until
programming button is pressed to return
machine to idle mode.
The dryer control shall not start until
the detected short circuit is removed.
Regardless of condition of short circuit,
Error Code will be displayed until
programming button is pressed to return
machine to idle mode.
Power machine down and try to reset
control. Varify voltage to the control
board. Check ground to board. Replace
control board if error can not be cleared
Power machine down and try to reset
control. Varify voltage to the control
board. Check ground to board. Replace
control board if error can not be cleared
Power machine down and try to reset
control. Varify voltage to the control
board. Check ground to board. Replace
control board if error can not be cleared
on the model selection header is used
that does not have a model designated
for it. check connector marked Jumpers
on the control board.
If connected to DexterLive, Disconnect
cable, and preform a soft restart by
holding down the program button on
power up.
Preform Soft restart.
contact your Dexter factory representive.
Internal IC issue. Replace control.