Purging Products from the toaster
During normal operation, if it ever becomes necessary
to purge a product from the toaster, follow these steps:
1. While in Ready or Wait mode, press and hold the
NeXt button until the product have been purged
from the unit. This will speeds the unit up, forcing
the product out of the toaster.
2. Once the product is purged, release the NeXt
button and the unit will return to normal operating
speed.
Note: Product is always purged out of the front of
the toaster using the NeXt button. It is Not pos-
sible to purge product backwards through the unit.
only the NeXt button will purge product.
shutting down the CtX-200l
Follow these steps to shut down the toaster:
1. Turn the power off.
2. The fans continue to run and the display reads:
OK to Clean
45 minutes Remaining
3. The Cool Down mode will continue for 45 min-
utes, counted down on the display, and the unit
will shut down automatically when complete.
Note: If the unit requires any internal maintenance,
be sure to completely shut down the unit.
IMPortaNt
do Not unplug the power cord when the unit is
in cool down mode. Wait for the 45-minute cool
down period to complete before unplugging the
power cord.
WarNING
to avoid possible personal injury and/or dam-
age to the unit, all inspections, tests, and repair
of electrical equipment should be performed
by QualIfIed serVICe PersoNNel. the unit
Must be completely shut down and unplugged
before performing any internal service, except
when electrical tests are required. use extreme
care during electrical circuit tests. live circuits
will be exposed.
P/N 1011038 06/09
McDonald's
oPeratIoN (continued)
reset to factory defaults
Inadvertent changes to the settings of the CTX-200L
could affect how the unit operates. If a fault message
appears, it is recommended that you first attempt to
restore the settings to the factory defaults. This will
restore all settings and parameters to McDonald's
corporate specifications.
Note: the CtX-200l should Not be unplugged
during normal operation or during the 45-minute
cool down period.
Follow these steps to reset the Factory Defaults:
1. Turn the power off.
2. Turn the power on.
3. Listen for the unit to click three times, then imme-
Note: the display will then go blank.
4. Turn the power off and then back on.
5. Wait for the 20-second countdown to complete.
Note: the unit will then display Muffin Wait.
6. Preheat the unit and test for proper operation.
Note: If after resetting the factory defaults the
unit continues to display a fault/error message, turn
the power off and unplug the power cord. Wait a
few seconds and then plug the power cord back in.
then repeat steps 2 through 6. If the unit still dis-
plays a fault/error message, immediately call your
authorized service agency for assistance.
Changing the display language
Follow these steps to change the display language
between English and French:
1. At any time during power off (but connected to
2. Press the NeXt button to select the desired
3. After 3 seconds, the change is stored into
9
Club ToasTer CTX-200l
diately press and hold the PreV and NeXt but-
tons until the display reads Factory Defaults
Set.
power), cool down, warm-up, or normal operation,
press the seleCt button.
language and then release the button.
memory.