- ページ 11

キッチン家電 A.J.Antunes Roundup VS-200A-A1のPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。A.J.Antunes Roundup VS-200A-A1 16 ページ。 Roundup variety steamer

To avoid possible personal injury and/or damage to the unit, inspection, test, and repair of electrical equip-
ment should be performed by qualified service personnel. the unit should be unplugged when servicing,
except when electrical tests are required.
problem
unit does not operate.
unit does not steam
product evenly.
No heat or insufficient
heat. correct tempera-
ture is 360°f–390°f
(182°c– 199°c),
measured continuously
on generator surface in
the cavity.
unit flooding or always
steaming
OR
unit floods overnight.
unit heats but will not
steam.
unit steams too little
or too much each time
MOMENtaRY switch is
pressed.
P/N 1010591 Rev. E 03/12

trOublesHOOtInG

possible cause
Power cord not correctly plugged in.
the power cord and/or electrical plug
is damaged.
Hi-Limit Thermostat has been tripped
or is defective.
Loose connections.
Power switch is inoperable.
Main water supply.
Needle Plate clogged.
spray tube partially clogged.
Diffuser missing.
thermostat defective.
generator defective.
Heavy deposit buildup on Generator.
incorrect water pressure.
Potentiometer defective.
solenoid defective.
solid state timer defective.
Water supply not connected.
Potentiometer set too low.
Potentiometer not adjusted properly.
VAriety SteAMer (VS-250)
warnInG
Plug in the power cord correctly.
inspect electrical wire, plug, and receptacle.
Reset circuit breaker. contact your mainte-
nance person or authorized service agency if
it trips again.
check and tighten all connections.
contact your maintenance person or
authorized service agency for service.
Verify water pressure is 20–30 psi.
clean Needle Plate according to the
Maintenance section of this manual.
clean the spray tube according to the
Maintenance section of this manual.
Reinstall/replace Diffuser.
Remove one wire from thermostat. test for
continuity. Replace if open.
Disconnect one wire from Generator. Check
continuity for approximately 16 ohms resis-
tance. Replace if necessary.
clean unit according to Maintenance section
of this manual.
Verify water pressure is 20–30 psi.
Read 0-2 Vdc at terminals while rotating shaft.
Replace if defective.
Read line voltage at solenoid leads for 1/2
second every 10 seconds during steaming.
solenoid should click when powered. if not,
replace.
Replace solid state timer.
connect water supply.
adjust Potentiometer according to the
Maintenance section of this manual.
adjust Potentiometer according to the
Maintenance section of this manual.
11
corrective action
A.J. Antunes & Co.