(D) INSTALLATION
INSTALLATION NOTES AND CAUTIONS:
— The Aqua Flo AQUV Water Disinfection System is designed for installation on the cold water line only at the point of entry (POE). The system must
be installed in accordance with all local, state or provincial regulations.
— The system requires a constant power supply of 110V AC.
— It is strongly recommended to have a dedicated electrical circuit for the UV system. A CSA or equivalent certified surge protector must be installed
to protect the ballast from electrical surges. We recommend surge protector rated for a clamping voltage of less than 400 Volts, response time of
less than one nanosecond, and energy absorption of at least 600 Joules.
— The AQUV-20, AQUV-12 systems have been designed for maximum water flow rates of 20 US GPM (70 liters per minute) and 12 US GPM (45 liters
per minute) respectively. If higher flow rates exist occasionally, it is recommended that a flow restricter be installed at the inlet port (12
US GPM for AQUV-20 and 12 US GPM for AQUV-12.
— The system should be installed indoors in a protected area where the temperature does not fall below 4°C (40°F).
— For optimum performance, the system should be wall-mounted in a vertical position with the lamp connector at the top.
— It is highly recommended to install bypass piping with a shut-off valve around the unit. This way you can still have water in case you need to
remove the UV unit for service.
— Provide a minimum clearance of 3 feet above the unit for lamp replacement.
— Use only Teflon tape for all connections. Do not use any other sealant on the threads.
DIMENSIONS
AQUV 12R22
24.00
16.00
6
8.50
AQUV 20R22
24.00
16.00
CAUTION!
** Install a pressure regulator and water hammer
arrestor if pressure exceeds maximum rating of
100 psi at any time. Note: If daytime pressure is
over 80 psi, night time pressure may exceed
maximum pressure rating.
NOTICE
Check with your local public works department
for applicable local plumbing and sanitation
codes. Follow local codes if they differ from
the standards used in this manual. Otherwise,
carefully follow the instructions in this manual.
Canature is not liable for any non-compliance
with local requirements
8.50