CORRECT
Quartz dome is past gland
nut O-ring and is touching the
inside top end of the gland
nut. Caution: Do not push
hard as it can break the quartz
dome.
12
Thinner O-Ring
Quartz
Dome STOP
position
Thicker O-Ring
WRONG
Quartz dome is NOT past
gland nut O-ring and is NOT
TOUCHING the inside top end
of the gland nut.
Fig.5
13
10. Carefully slide the quartz dome with gland nut
attached into the opening at the top of the UV
chamber and hand-tighten the gland nut into
place.
CAUTION!
Do not overtighten the gland nut as it can
break the quartz dome.
Broken quartz domes are not covered
- Do not use pipe dope or tape on these top threads before
attaching gland nut.
11. Slowly open supply-valve and valves before and
after UV system. Check for leaks. Do not
proceed to next step until leaks are fixed.
12. From the top of the gland nut, drop the lamp
spring into the quartz dome.
13. Holding the top 4-pin end of the lamp
carefully slide the lamp into the quartz dome
and attach the lamp pins to the lamp connector.
The lamp connector fits over the pins in only
one orientation.
14. Slide the lamp connector cover over the gland
nut and tighten the screw on it.
14
NOTE
under warranty.