SYMPTOM
Burner won't
mm on
TROUBLE
SHOOTING
CHART
- AUTOMATIC
PILOT
& VALVE
POSSIBLE
CAUSES
CORRECTIVE
ACTION
1. Pilot flame too large or too small.
2. Dirt in pilot orifice.
3. Detective automatic pilot section in
combination control valve.
4. Detective thennocouple.
5. Defective combination control valve.
6. Wall thermostat models - manual reset
blocked flue switch tripped.
1. Re-adjust pilot flame using adjustment on
combination control valve.
2. Clean pilot orifice with air or solvent, do
not ream.
3. Replace entire combination control vane.
4. Replace thermocouple.
5. Replace valve.
6. Reset switch, see Page 6 and blocked flue
section below.
TROUBLE
SHOOTING
CHART
- BLOCKED
FLUE
SWITCH
(FOR USE BY A QUALIFIED SERVICEMAN)
POSSIBLE CAUSES
CORRECTIVE ACTION
1. Blockage in
A. Check vent pipe for blockage, such as bird nest, wasp nest, twigs, leaves, etc.
vent pipe
B. Check inside the bottom of the vent pipe to make sure the top of the draft diverter did not
rip the inner liner causing it to block part of the vent opening.
C. Check that no insulation from the header plate got caught on top of the draft diverter when
the heater was inserted into the wall.
D. Check that the vent cap is properly installed, not shoved too tar down on the vent pipe.
2. Burner is
A. Check the manifold pressure.
overfiring
B. Check the rate, NOTE:
This appliance was orificed for elevations up to 2,000 feet. When
installed at higher elevations refer to orifice chart in controls section of instructions for
proper orifice size and re-orifice accordingly.
3. Colxect vent system.
3. hnproper vent
system
A. Vent too short
B. Restriction in
vent system
caused by ofl;ets
C. Incorrect vent pipe
4. Inconect header
4.
plate location
5. Vent pipe not do,am
5. Use a base plate (obtained from the vent pipe manufacturer) on top of our header plate.
on the header plate
This wilt lock the vent pipe down and prevent the draft diverter from shoving it up.
securely
6. Loose connections
6. Check the connection on both the switch and the gas valve. Tighten if necessary.
on the vent safety
wiring harness
A. The vent should tenninate a minimum of 12 feet above the floor. See Figure 2. Also, the
top of the vent must be at least 2 foot above any obstacle within a 10 foot radius, including
the roof. See Figure A.
B. All type "B" vents shall extend in a generally vertical direction with ofl;ets not exceeding 45
degrees, except that a vent system having not more than one 60 degree ofl;et may be allowed.
Any angle greater than 45 degrees tiom the vertical is considered horizontal.
The total
horizontal mn of a vent plus the horizontal vent connector shall be not greater than 75 percent
of the vertical height of the vent.
Any ofl_ets used should be as far above the drafthood as possible to allow a venting action to
begin before any restriction is encountered.
C. Use listed BW type vent pipe. Do not use tansite or any other type of ceramic pipe t\_r venting.
Do not use single wall pipe. When venting into a masonry chimney the chimney must be
properly lined and sized for this gas furnace. The use of type B or flexible chimney liner is
recommended.
The header plate must be 65-3/4" above the floor plate. See rough-in instructions.
I
DO NOT
BYPASS
THE
BLOCKED
FLUE
SWITCH
To do so could
expose
the consumer
to property
damage,
personal
injury
or possible
death.
Page 16