Calypso First Stage Service Manual
SYMPTOM
Restricted airflow/high inhalation
resistance through entire system
Insufficient medium pressure
High intermediate pressure (leakage
or freeflow through second stage)
Leakage of air from ambient ports of
piston cap
Leakage of air from inlet fitting
NOTE:
more information, contact Aqua Lung's Technical Services Department for assis-
tance with problems not described here.
CAUTION:
lator must be performed during a complete overhaul, according to the pre-
scribed procedures for scheduled, annual service. Do not attempt to perform
partial service.
Table 1 - Troubleshooting Guide
POSSIBLE CAUSE
1. Cylinder valve not completely
opened.
2. Cylinder valve requires service
3. Conical filter (13) contaminated
4. Insufficient medium pressure
1. Low inlet pressure
2. Main spring (7) weakened
1. HP seat (6) damaged or worn
2. Piston o-rings (3,5) damaged and
worn
3. Crown o-ring (5) damaged
4. Crown orifice (11) sealing surface
damaged
5. Damaged piston (4)
1. Piston shaft o-ring (5) damaged or
worn
2. Piston head o-ring (3) damaged or
worn
1. Inlet fitting o-ring (14) damaged
This is a partial list of possible problems and recommended treatments. For
Recommended treatments which require disassembly of the regu-
TREATMENT
1. Open valve. check fill pressure
2. Connect to a different cylinder
3. Replace filter with new
4. See below
1. Refill test cylinder
2. Replace main spring
1. Replace HP seat
2. Replace o-rings
3. Replace o-ring
4. Replace crown
5. Replace piston
1. Replace o-ring
2. Replace o-ring
1. Replace o-ring
9