- ページ 4
浄水器 Aqua Medic Easy Line 90のPDF 操作マニュアルをオンラインで閲覧またはダウンロードできます。Aqua Medic Easy Line 90 6 ページ。 Reverse osmosis unit
Easy Line 90
The pure water, produced in the first 2 h has to be discarded, because it may contain residues
of the desinfection liquid which has been filled in the module for storage. After 2 hours, the
water can be used.
4. Use of the water
Rejection rate:
The rejection rate of the membrane for the most salts and organic substances varies between
95 and 98% (except nitrate and silicate). The water can be used in various areas:
In salt water aquariums:
- for the preparation of sea water,
- for the preparation of „Kalkwasser" or Calcium enriched water,
- for the refilling of evaporated water.
In the fresh water aquaria:
- pure - for breeding soft water fishes (Discus, etc.),
- hardened up with Hydrocarbonate in all fresh water tanks,
- pure - for the refilling of evaporated water.
In households:
- for the preparation of drinks and meals,
- for car batteries and flat irons,
- for home plants, especially orchids, bromelids and cacti.
In laboratories and industry:
- everywhere, where up to now destilled or deionised water has been used and a conductivity
of 20 - 50 µS/cm is accepted.
5. Maintenance
- Prefilter. If the tap water is not extremely polluted, a yearly replacement of both prefilters
will be sufficient. If the water is higher polluted, the filters have to be changed more often -
as required. If the prefilter is blocked, the water production will slow down.
- Membrane. The membrane normally has an lifetime of several years. Afterwards, it has to
be replaced.
6. Failures
- The waste water flow rate is too low:
Test the prefilter on blocking. Connect the water inflow directly to the module. If the waste
water flow is normal again, change the prefilter. If the flow is still too low, the flow
restrictor has to be renewed
- The pure water flow rate is too low:
Check the waste water flow rate. If it is low too, change the prefilter.
- The tap water pressure is too low:
If you are connected to a municipal water supply, you are not able to influence the water
pressure. For the reverse osmosis unit, a minimum water pressure of 3 bar is required.
3,0 - 3,75 l
approx. 14 l