データロガー aqua metro Contoil DFM 8EDMのPDF 取付・取扱説明書をオンラインで閲覧またはダウンロードできます。aqua metro Contoil DFM 8EDM 20 ページ。
®
CONTOIL
DFM 8EDM to a fleet manager or
to a GPS system
Before you start with the electrical connection of the system, you must have done a correct installation of the delive-
red components. This installation must be done by an authorized and certified company/person.
Please be aware: an incorrect installation may destroy the DFM-System and damage your vehicle. In this case, Aqua-
metro will deny all responsibilities.
Function description
• The supply line starts from tank, goes to the pre-filter, to the fuel pump, to the supply-line-flow-meter, to the fine filter and than to the in-
jection pump.
• The injection pump injects the needed amount of fuel and returns the rest over a return line to the tank. Also a so called "leak-line" from
each injection valve are collected to one line and connected over a t-piece to the return line (see Schematic of a configuration).
• The return line ends to the tank.
This is a global description. Deviation from it may occur.
Installation description
®
The CONTOIL
DFM 8EDM has 2 flow chambers: supply line chamber and return line chamber. Those chambers are marked with a "S" for
supply and with a "R" for return. The chamber fuel entry is marked by an arrow (see pictures).
®
Mount the CONTOIL
DFM 8EDM to a vibrations-free place on the vehicle (NOT on the engine!). Connect the supply line chamber in-bet-
ween the fuel supply line. Connect the return line chamber in-between the fuel return line. Tight all the connection.
Electrical connection
The CONTOIL
®
DFM 8EDM has 4 wires:
Wires color
Function
White
12 - 24 VDC
Brown
GND
Green
Open drain (out1)
Yellow
Voltage Level (out2)
Connect the described wires above according to the instruction on the installation manual of the fleet manager or GPS system.
10
Remark
Input voltage 12 - 24 VDC from the DFM-BC or from another source. If you use another
source, make sure the voltage is stable and filtered.
Ground (take the same ground like the 12 - 24 VDC source).
When a signal is generated, this line will go to ground.
Below 0.8 VDC = no signal (logic 0)
Between 0.8 - 2.8 VDC is undefined zone
Over 2.8 VDC = signal (logic 1)
®