- ページ 10
セキュリティセンサー CP Electronics MWS3A-AT-PRMのPDF 製品マニュアルをオンラインで閲覧またはダウンロードできます。CP Electronics MWS3A-AT-PRM 17 ページ。 Rd ceiling microwave presence detector-switching
CP Electronics MWS3A-AT-PRM にも: インストレーション・マニュアル (20 ページ)
Application examples
Example 1: Offices and corridor
Example 1 shows two small offices, each with four downlighters controlled by a single MWS3A-AT-PRM sensor. These
are set-up for Presence detection such that the lights turn on when anyone enters the room and turn off when the room
is vacated.
Similarly, the corridor lights are controlled by two sensors such that if either sensor detects movement, all of the corridor
lights turn on. Note that only one sensor is physically wired to the lighting circuit.
In this arrangement the devices in each room need to be programmed with a unique Local Code, although the two
devices in the corridor share the same code so that they can both control the corridor lights.
In addition, each unit needs its Time Adjustment Period set to an appropriate value.