Detection pattern
Technical data
MWS1A-PRM
Supply Voltage
Frequency
Power consumption
Load
MWS1A-PRM-LV
Supply Voltage
Power consumption
Load
MWS1A-PRM-VFC
Supply Voltage
Frequency
Power consumption
Load
Part numbers
MWS1A-PRM
MWS1A-PRM-LV
MWS1A-PRM-VFC
Frequency compatibility
The allowable frequency of operation of this product is different depending on region. Please select the correct order
code using the table below.
Code suffix
blank
UK, China, India, Middle East, Malaysia, Hong Kong, Singapore
-R2
UK, France, Portugal, Germany, Switzerland, Austria, Slovak Republic, Republic of
-R3
-R4
-R5
4
230VAC +/- 10%
50Hz
On 1.15W
Off 790mW
10A of lighting and or ventilation including
incandescent, fluorescent, compact
fluorescent, low voltage (switch primary of
transformer).
Min 11.5VDC max 36VDC, min 10VAC
max 26.5VAC
On 1.01W
Off 712mW
Low voltage supply with relay output rating
16A resistive 10A inductive
230VAC +/- 10%
50Hz
On 1.15W
Off 790mW
Normally closed contact
2 Amp maximum
Minimum load 100mA
Normally open contact
6 Amp fluorescent lighting and resistive
3 Amp compact fluorescent lighting
3 Amp low energy lighting
3 Amp low voltage lighting (switch primary
of transformer)
Microwave presence detector (wall mounting)
Microwave presence detector (wall mounting) Low Voltage
Microwave presence detector (wall mounting) Volt Free Contact
Region
Australia and all of Europe except:
Ireland
France, Portugal, Switzerland
Germany, Austria, Slovak Republic
Republic of Ireland
Dimensions
All models
Weight
Terminal Capacity
Time out period
Light level
Fixing method
Temperature
Humidity
Material (casing)
Compliance
Safety
Frequency
IMPORTANT NOTICE!
10.687GHz
This device should be installed by a
10.525GHz
qualified electrician in accordance with
the latest edition of the IEE Wiring
Regulations and any applicable Building
9.900GHz
Regulations.
9.350GHz
10.41GHz
Fluorescent lighting (max 6 fittings
recommended)
For fluorescent lighting total power factor
correction capacitance must not exceed
40μF.
3 Amp fans and ventilation equipment
Switch SON lighting loads via a contactor
Minimum load 100mA
0.1kg
2
2.5mm
Adjustable 10 seconds to 99 minutes .
Optional adjustment by using IR
programming handsets.
Surface fixing
35mm deep plastic surface mount moulded
box.
Flush fixing
25mm steel backbox or 25mm deep cavity
backbox.
-10ºC to 50ºC
5 to 95% non-condensing
Flame retardant ABS Type Class 2
EMC-2014/30/EU
LVD-2014/35/EU
The microwave radiation emitted by these
units is extremely low power. At a distance
of > 50mm the power density is <6% of the
ANSI IEEE C95.1 –1991 recommended
microwave power density.
At a distance of 5mm from the unit it is
<84% of recommended power density.
Ref: #WD406 Issue 5