Installation guide
Billi Quadra – Firewall Tower
Commissioning – Quadra
Turn On the Water Supply
Turn on the water supply tap and ensure that
there are no leaks. Remove front panel of unit
and remove packing foam from under filter
canister. Ensure filter canister is securely
locked back into place. Replace front panel.
Turn On Electricity
Turn on power switch. Check normal time
display is showing. Status line should display
'INITIAL FILL'. Boiling and chilled water tanks
are now filling. Dispenser icons flash orange
slowly.
Cold Water
During
the
initial
automatically opens to fill the cold tank. After
approximately 1 minute, cold water will begin to
flow from the dispenser outlet. Water will
continue to run for a further minute to flush and
condition the filters.
IMPORTANT: Container should be placed
under the dispenser outlet to collect any
water being dispensed during the filter
flush.
Hot Water (Auto Boiling Calibration)
Auto Boiling Point Calibration: The hot tank will
first fill to the height of the low level sensor. The
water is then heated until it reaches boiling
point. The unit will continue to boil for up to 30
seconds
while
the
calibrates.
WARNING: Steam and small amounts of hot
water may be discharged from the outlet
and
vent
during
calibration is underway the hot water
indicator will flash yellow. The hot water set
point is calibrated 1.5°C below the boiling
point. Once calibrated, the unit will resume
normal operation and the calibration data
will be saved. The unit will not re-calibrate
under normal circumstances.
fill,
cold
water
valve
temperature
sensor
this
period.
While
Setting the Programs
The Quadra operational settings have been
factory set for a typical installation. Clock is set
to Eastern Standard Time (EST). Refer to
Quadra User Guide for setting instructions. In
some installations, boiling water delivery
settings may need to be changed as outlined
below.
Tube length setting
The Quadra's boiling water flow rate slows
briefly as water first enters the cup to prevent
splashing. Correct timing of the moment of
reduced flow is dependent on the length of the
tube between the Quadra module and the
dispenser. The standard timing is set for a tube
length of 500mm but this setting can be simply
altered to suit the installation. After installation,
measure the length of the red tube from the
underside of the dispenser to the boiling water
outlet fitting. If the measured length is less than
450mm or greater than 550mm, the correct
value should be set in as follows:
1. Press
SELECT. Display changes to
menu selection mode.
2. Press
DOWN 4 times. Shaded curser
shows 'INITIAL SETUP'.
3. Press
SELECT. Display shows:
Press
SELECT. '0500 mm' flashes.
4.
Press
or
buttons to enter the correct
5.
tube length.
6.
Press
SELECT.
Press
BACK twice to return to normal
7.
display.
8