- ページ 15
産業機器 Allied Systems LONG REACH CCHAのPDF インストレーション・メンテナンス・サービス・マニュアルをオンラインで閲覧またはダウンロードできます。Allied Systems LONG REACH CCHA 19 ページ。 Carton clamp with load stabilizer
4. Turn on the truck's power and activate the posi-
tioning cylinders several times to bleed out trapped
air.
Notice
Equipment damage and loss of perfor-
mance could result if air is trapped in the
hydraulic system.
Activate the hydraulic functions several
times after hydraulic service has been
performed, to bleed trapped air out of the
system before returning attachment to
service.
5.6 Cylinder Disassembly
1. Remove the cylinder from the attachment. See
removal instructions.
2. Clamp the cylinder lightly at the base end in a soft
jawed vise. Use a block or other support under the
rod end of the cylinder. (Figure 5-2)
Figure 5-2, Cylinder Vise
3. Spread and remove the retaining ring from the gland
cap.
4. Push gland inward 1 inch and pry out lock ring.
5. Remove the rod assembly from the cylinder tube.
6. Clamp the rod assembly in a soft jawed vise on the
wrench flats, not on the rod surface. If the rod
does not have wrench flats use two pieces of wood
on both sides of the rod to prevent scaring. (Figure
5-3)
45-034, REV. 5/18
Figure 5-3, Cylinder Shaft
7. Remove the piston retaining nut and remove the
piston. (Figure 5-4)
Piston
Piston Nut
Figure 5-4, Rod Assembly
8. Carefully pry up on the piston seals using a blunt
tip screw driver being careful not to scratch the seal
grooves. Cut the seals to remove from the piston.
(Figure 5-5)
Figure 5-5, Piston Seal
Retaining Ring
Lock Ring
Gland Cap
15