- ページ 7

バスタブ ABACUS PiscesのPDF インフォメーション・パケットをオンラインで閲覧またはダウンロードできます。ABACUS Pisces 17 ページ。 Adjustable height bath

ABACUS Pisces インフォメーション・パケット
ELECTRICS
1. 5 Amp IP65 rated Non Switch Fused Spur, with 2m of 1.5mm 3 core round flex trailing. Cable should be housed in
flexible conduit and located at the tap end of the bath, positioning and specification to be in accordance with IEE
regulations. The Spur box should be mounted between 300-500mm off the floor.
2. Where a Whirlpool is fitted then 13 Amp IP65 rated Non Switch Fused Spur fused spur is required as point 2.
A 30mA RCCD or RCBO is required in compliance in accordance with 17
located just outside the bathroom or on the consumer unit covering that area of the building.
Earth Bonding and Cross Bonding are to be fitted and tested for continuity in accordance with IEE regulations.
Abacus Pisces 069/Info.P 04/14v1a
1700 Pre Installation Requirements
Electrical Connection & Earth Bonding
Image for Plumbing and Electrical Supplies (2nd Spur fuse for Whirlpool)
(Reference purposes only) -Side & end wall feeds.
th
Edition IEE regulations. This should be
7