- ページ 8
マトリックススイッチャー AVProConnect AC-MX88-UHDのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。AVProConnect AC-MX88-UHD 13 ページ。
Read EDID from output y and write to User EDID n of input
x – (n = 1 to 3)
Read EDID from output y and write to User EDID n of
All inputs – (n = 1 to 3)
Get Status Information
Output a report giving the current status of the matrix switcher (2)
Read the input connection status (4)
Read the output connection status (4)
Read input HDCP status (4)
Read output HDCP status (4)
Read output channel settings (4)
Read output On/Off states (4)
Read External (de-embedded) audio status (4)
Read input EDID setting (4)
Read all network settings (5)
Read cascade mode status (4)
Set Cascading Mode
Turn cascading mode on
Turn cascading mode off
Other Commands
Power off the matrix switcher (enter standby mode)
Power off the matrix switcher (exit standby mode)
Help, list all available commands (2)
Reset to factory defaults
Notes:
(1)
This command generate a large report giving detailed information about the current
status of the matrix switcher.
(2)
This command lists all the commands that the matrix switcher supports.
(3)
These EDID commands output an ASCII data block that lists the values of the requested
EDID data values in hexadecimal notation.
(4)
These commands respond with a short message, usually one line, giving the requested
information.
(5)
The IP status command will respond with all the current IP settings: Host IP address,
Subnet mask, Router IP address, TCP/IP port number and the DHCP setting.
AVProConnect
AC-MX44-UHD & AC-MX88-UHD
>@WEWI[x]U[n]O[y]
>@WEWIAU[n]O[y]
>@RSTA
>@R8001
>@R8002
>@R8003
>@R8004
>@R8006
>@R8007
>@R8008
>@R8009
>@R8012
>@R8017
>@WSDBGEN
>@WSDBGDIS
>@WSPF
>@WSPN
>@RH
>@WSDF
8