- ページ 9
浄水器 Aqua Science Fleck 5600 SXTのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。Aqua Science Fleck 5600 SXT 12 ページ。 Digital water softener system
Fleck 5600 SXT Digital Water Softener System Installation Manual
Fleck 5600 SXT Digital Programming
Cycle
Up/Down
Button
Arrow
800-767-8731
Step 1
To enter the programming mode you must first set the time to 12:01 PM. To do this use
the up arrow or down arrow to change the time. You will see TD in the upper left corner
when the time is being set.
After you set the time to 12:01 PM
1.) Press the cycle button once
2.) Press and hold the up and down arrow buttons at the same time until the screen
changes to look like Step 2 below
Step 2
Press and hold the Up and Down Arrows at the same time for about 3 to 5 seconds
until you see the setting DF (Display Format) GAL.
The value of GAL should show up as the default. If not, use the UP or DOWN Arrow to
select GAL.
Press the Cycle button to advance to the next step.
Step 3
The next setting you'll see is VT (Valve Type). Set that to dF1b (Downflow 1 Backwash).
Press the Cycle button to advance to the next step.
Step 4
The next setting you'll see is CT (Control Type). Set that to Fd (Metered Flow Delayed).
Press the Cycle button to advance to the next step.
Step 5
The next setting you'll see is NT (Number of Tanks). Set that to 1.
Press the Cycle button to advance to the next step.
9