- ページ 12
タッチパネル DFI VP070-M8MのPDF クイック・インストール・マニュアルをオンラインで閲覧またはダウンロードできます。DFI VP070-M8M 14 ページ。 Arm-based in-vehicle fanless touch panel pc
Jumper Settings
X Jumper Settings- Power Board
Host Bus Communication
Reserved
TX/RX UART (default)
24V/12V Select (Output Voltage)
12V (default)
24V
Power On Delay Switch (Delay On/Off)
On, delay duration defined by 4 and 5
Off, delay = 3 seconds by default
Power Off Delay Switch (Delay On/Off)
On, delay duration defined by 6, 7, and 8
Off, delay = 0 seconds by default
Power On Delay Time Select (Delay Duration)
10 seconds (default)
30 seconds
1 miniute
5 minutes
Quick Installation Guide | VP070-M8M
JP3 / JP4
High Active (default)
1-2 On
Low Active
2-3 On
SW1
1 On
1 Off
SW1
2 On
2 Off
SW1
3 On
3 Off
SW1
4 On , 5 On
4 Off , 5 On
4 On , 5 Off
4 Off , 5 Off
Remote Switch High/Low Active
JP2
1-2 On
2-3 On
11