FIRST TIME USE
With the help of a screwdriver, unscrew the screw on the right side of
the product and remove the front panel (Fig.3).
Position the base correctly and secure it to the 3-module recessed box
or to the wall using screws and dowels supplied.
For fixing the dowels, pierce the wall with a tip of 5 mm diameter.
Fig.3

ELECTRICAL CONNECTION: POWER SUPPLY

Attention: The electrical connection has to be carried out by spe-
cialized technical staff.
It has to be provided with an device, to be disowned from the detector
and the feeding net, with minimun 3 mm contact distance in accordance
wit has written in the "European Standard EN 60335-1".
The gas detector Beta series can work at 230Vac or 12Vdc:
l At 230Vac-50/60Hz using the terminals "L" and "N" (Fig.4).
L
N
230Vac-50/60Hz
Fig.4
In this case the terminals "+" and "-" can supply power to an external
device at 12Vdcv max 50mA.
l At 12 Vdc using the terminals "+" and "-" ( Fig.5)
+
-
12Vdc
Fig.5
Immediately after you have give power the detector enters in stabili-
zation mode.
The Beta series gas detectors mod. 760 CO and mod. SE320EC
have a lifestime of more than 6 years (normal conditions) while the gas
detectors series Beta 760/10 CO and mod. SE340EC have a lifetime
of 10 years (normal
conditions)..
STABILIZATION MODE
Once switched on, the detector needs a stabilization period of about
two minutes before working properly. During this period, the detection
functions are inhibited.
This state is represented by the synchronous flashing every 8 seconds
of the GREEN and RED LEDs.
After the stabilization period has elapsed, the detector switches to nor-
mal state ON.
DETECTOR'S MODE
MODE ON
l
Beta
The gas detector
keeps the GREEN LED steadily ON.
This means that the Beta Gas Detector is active in the detection of
Carbon Monoxide "CO".
The table "Tab.2" shows all the operating modes of the
tector.
Each MODE is recognizable by a specific number of flashes and / or
"Beeps" of the buzzer over a period of 1 minute.
+
-
12Vdc
Beta
3
SELF TEST
l
Beta
The
Gas Detector performs an automatic self-test every 10 min-
utes.
This is a check of the electronic components inside it, including the
sensor, to ensure the full functionality of the detector. The SELF-TEST
is an auto-check of the detector that is not shown to the user.
If the Self-Test detects problems, the detector switches to FAULT STA-
TUS.
FAULT MODE
l
In this status the gas detector emits 2 "Beeps" and 2 "flashes" of the
YELLOW LED per minute (Tab 2).
This means that the
erly and gas detection is no longer guaranteed.
The gas detector must be replaced.
You can silence the 2 Beeps for a 24-hour period by pressing the
TEST / HUSH key (see TEST/HUSH paragraph).

ALARM MODE

l
In this mode the detector is detecting a concentration of carbon
monoxide over the alarm thresholds. In this state, the detector emits
"Beeps" and the RED LED flash intermittently.
Only if the amount of gas measured in air is less than 300 ppm it is
possible to silence the buzzer for a period of 15 minutes by pressing
the TEST / HUSH button (see TEST / HUSH paragraph).
After that period, if the gas concentration exceeds the alarm thresh-
olds, the BUZZER will be automatically switched on.
ALARM + FAULT MODE
l
l
(It corresponds to the status of ALARM MODE + flashing of the YEL-
LOW LED).
In this state, the detector emits "Beeps" and the RED LED and YEL-
LOW LED flash intermittently.
The detector is detecting a concentration of carbon monoxide over the
alarm thresholds and simultaneously one of the two following cases
are occurring:
- CO concentration is higher than the full scale.
- the detector is experiencing an abnormal operation.
Only if the amount of gas measured in air is less than 300 ppm it is
possible to silence the buzzer for a period of 15 minutes by pressing
the TEST / HUSH button (see TEST / HUSH paragraph).
After that period, if the gas concentration exceeds the alarm
thresholds, the BUZZER will be automatically switched on.
If, once the gas leak alarm ceased, the detector is in FAULT MODE, it
must be replaced.
END OF LIFE OF THE SENSORS' STATUS
l
In this mode, the gas detector emits 3 "Beeps" and 3 LED YELLOW
LED flashes every minute (Tab 2).
The gas detector has exceeded the maximum time in which the
operation is guaranteed. The gas detector must be replaced.
MODE
FAULT
ALARM
ALARM + FAULT
END LIFE
Tab. 2
gas de-
CHARACTERISTICS OF THE OUTPUT
Beta
The
gas detector provided with a relay with free contacts with-
out tension; contact range 8A 250Vac/ 30Vdc.
Beta
gas detector is no longer functioning prop-
= N° Flash led/minute
= N° Beep/minute
N°Flash & "Beep"/minute
&
&
-
-
N°2
N°60
-
N°60
-
N°60
-
-
N°3