Service Manual
351FFOP40N, 351FFOP50N, 351FFOP40L, 351FFOP50L

Part Testing

CAUTION: Components Can Be Hot
Follow these pre-maintenance steps before servicing
your Cooking Performance Group Floor Fryer

PRE-MAINTENANCE:

1.
Turn thermostat to the "OFF"
position (Fig. 1)
2.
Turn knob, on combination gas valve,
to the "OFF" position, align with
"RED" dot (Fig. 2)
3.
Turn off gas supply to unit (Fig. 3)
(Supplied by others)
4.
Allow unit to cool as needed

GAS COMBINATION VALVE:

Thermopile voltage with pilot light on
= 250 - 750 millivolts DC with thermostat
in "OFF" position (Fig. 4)
If too low, adjust pilot light flame strength,
see below
Knob in "ON" position, Thermostat in "ON"
position, coil voltage should be higher than
120 millivolts
If the coil voltage is below 120 millivolts DC,
replace combination valve
GAS COMBINATION VALVE
ADJUSTMENTS:
Adjusting Pilot Light Strength
1.
Remove screw cap covering pilot adjustment
screw, located next to the pilot light gas hose,
with a flat head screwdriver (Fig. 5)
2.
With a small flat head screwdriver, turn the
adjusting screw to increase or decrease pilot
light strength as needed
Counterclockwise = Increase
Clockwise = Decrease
3.
Reinstall cover cap when correct strength has
been reached
Pilot light strength check
1.
Pilot light should have a minimum
millivolt reading of 250, 500 or more is
recommended (Fig. 6)
4
FIG. 1
FIG. 3
FIG. 5
.
FIG. 2
FIG. 4
FIG. 6