- ページ 5
除湿機 ABATEMENT AQUATRAP AT150RSのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。ABATEMENT AQUATRAP AT150RS 6 ページ。 Lgr dehumidifier
Touch Pad Keys (Cont.):
PURGE.
Press the PURGE key to empty water from the pump reservoir.
During normal operation, the pump purges automatically whenever the
reservoir is full. The display will show the PURGE ON icon.
TO PURGE THE PUMP MANUALLY BEFORE TRANSPORTATION:
Stop dehumidification using the START/STOP key, and let the unit
sit for about 10 minutes. This allows water to drip from the coils.
Press PURGE to remove residual water.
DISPLAY.
Press the DISPLAY key to display "TIMER" CLOCK,
"TOTAL" CLOCK or "JOB" CLOCK while the machine has been turned
on. Pressing the DISPLAY key will advance which clock time is displayed.
Only ONE choice of clock time can be displayed at a time.
In STANDBY MODE, the default display is "TIMER" CLOCK time.
Press the DISPLAY key once to display the "TOTAL" CLOCK time.
Press it again to display "JOB" CLOCK time, which shows the
LAST JOB run time.
When the dehumidifier is operating in a pre-set "TIMER" run cycle,
the default CLOCK display is "TIMER" CLOCK time, which shows
the remaining run time of the CURRENT JOB. Press the DISPLAY
key once to display the "TOTAL" CLOCK time. Press it again to
display "JOB" CLOCK time, which counts the CURRENT JOB run
time.
When the dehumidification is running continuously without a
"TIMER" setting, the default CLOCK display is "JOB" CLOCK,
which shows the CURRENT JOB running time. Press the DISPLAY
key once to display "TIMER" CLOCK time, which reads "00:00".
Press it again to display the "TOTAL" CLOCK time.
If the DISPLAY key has not been pressed within 15 seconds, the
CLOCK time will revert back to its default display.
When error messages appear, "TIMER", "TOTAL" and "JOB"
CLOCK displays disappear. Press DISPLAY key once to get the
clock displays back once errors are cleared.
Operating Your Dehumidifier
Place the dehumidifier in upright position
If the dehumidifier has been laid down in a horizontal position for any time over
a few minutes, you must set it upright (vertical) for 30 minutes before starting.
Connect the drainage system
You can find the hose wrapped around the back of the machine. Unwrap the
entire hose and run it into a sink, toilet, drain, or bucket. Remove any kinks in
the hose. Use bleach in the condensate pump once a year to keep clean.
Plug in the electrical cord
The electrical cord is stored wrapped around the air outlet on the back of the
unit. Unwrap the cord and plug it into a standard outlet with the correct voltage
and amperage for the unit. If using an optional 230V to 115V converter that
allows you to plug in multiple units at the same time using your customers'
electric clothes dryer, stove or oven outlet, always check the voltage with a volt
meter.
Before Transporting Your Dehumidifier
Before moving the unit, make sure the pump is empty of water. Allow the unit to
sit for 10 minutes after stopping the dehumidification cycle. Push the PURGE
key to clear water. See "How to Use the Touch Pad Control Panel" for more
details.