- 1. Table of Contents
- 2. Safety Precautions
- 3. General Installation Instructions
- 4. Specifications & Dimensions
- 5. Conversion
- 6. Lighting Instructions
- 7. Operating Instructions
- 8. Cleaning & Maintenance
- 9. Troubleshooting
- 10. Explosion View Drawing
- 11. Spare Part List
- 12. Spare Parts List
- 13. Limited Warranty
Ensure gas supply and gas type, as shown on unit nameplate, agree.
Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the
National Gas Installation Code, CSA-B149.1, or the Propane Installation Code, CSA-B149.2 as
applicable and in accordance with local codes.
Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand.
Level the unit by turning the adjustment screw at the bottom of each leg. Do not slide unit with
legs mounted, lift if necessary to move unit.
Pipe threading compound must be resistant to the action of liquefied petroleum gases.
Caution: DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap
and water solution before operating unit.
THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY.
Combustible clearances:
6" sides (152 mm)
Noncombustible clearances:
0" sides ( 0 mm)
Do not obstruct the flow of combustion and ventilation air under the unit by the legs or behind
the unit by the flue.
Adequate clearance for air openings into the combustion chamber is required. Do not place
objects between the bottom of the unit and the counter top.
There must be adequate clearance for removal of the front panel. All major parts except the
burners are removable thru the front if the gas line is disconnected.
MODEL
G15
G15T
G24
G24T
G36
G36T
G48
G48T
Note: regulator – 75mm/3.25 inch depth. Dimensions above do not include regulator.
MODEL
G15
G15T
G24
G24T
G36
G36T
G48
G48T
GENERAL INSTALLATION INSTRUCTIONS
6" rear (152 mm)
4" floor (102 mm)
0" rear ( 0 mm)
4" floor (102 mm)
SPECIFICATIONS AND DIMENSIONS
WIDTH
DEPTH
IN. (MM)
IN. (MM)
15(381)
26.8(680)
24(610)
26.8(680)
36(915)
26.8(680)
48(1220)
26.8(680)
Griddle Surface Dimensions
WIDTH IN. (MM)
15(377)
24(606)
36(911)
48(1216 )
HEIGHT
# OF
IN. (MM)
BURNERS
16.3(415)
1
16.3(415)
2
16.3(415)
3
16.3(415)
4
4
BTU/PER
TOTAL
NAT/LP
BTU/Hr
30,000
30,000
30,000
60,000
30,000
90,000
30,000
12,0000
DEPTH
IN. (MM)
20(510)
20(510)
20(510)
20(510)
Pressure
In.w.c
6/10
6/10
6/10
6/10