- ページ 20

サーバー Dell D15UのPDF セットアップと仕様をオンラインで閲覧またはダウンロードできます。Dell D15U 21 ページ。
Dell D15U にも: セットアップと仕様 (19 ページ), インストレーション・マニュアル (36 ページ)

Dell D15U セットアップと仕様
Table 20. Computer environment (continued)
Description
Relative humidity (maximum)
*
Vibration (maximum)
Shock (maximum)
Altitude range
CAUTION:
Operating and storage temperature ranges may differ among components, so operating or storing
the device outside these ranges may impact the performance of specific components.
* Measured using a random vibration spectrum that simulates user environment.
† Measured using a 2 ms half-sine pulse.
20
Specifications of OptiPlex 5000 Micro
Operating
20% to 80% (non-condensing, Max dew
point temperature = 26°C)
0.26 GRMS random at 5 Hz to 350 Hz
Bottom half-sine pulse with a change in
velocity of 50.8 cm/sec (20 in./sec)
3048 m (10,000 ft)
Storage
5% to 95% (non-condensing, Max dew
point temperature = 33°C)
1.37 GRMS random at 5 Hz to 350 Hz
105G half-sine pulse with a change in
velocity of 133 cm/sec (52.5 in./sec)
10,668 m (35,000 ft)