Table 18. DC PSU status indicator codes (continued)
Power indicator codes
Blinking green

Hard drive indicator codes

Each hard drive carrier has an activity indicator and a status indicator. The indicators provide information about the current
status of the hard drive. The activity LED indicates whether the hard drive is currently in use or not. The status LED indicates
the power condition of the hard drive.
Figure 13. Hard drive indicators on the hard drive and the hard drive tray backplane
1. Hard drive activity indicator
3. Hard drive backplane on hard drive tray
Table 19. Hard drive indicator codes
Hard drive status indicator code
Flashes green twice per second
Off
20
Overview
Condition
When hot-plugging a PSU, the PSU indicator blinks green. This indicates that there is a PSU
mismatch with respect to efficiency, feature set, health status, or supported voltage.
CAUTION:
If two PSUs are installed, both the PSUs must have the same type of
label; for example, Extended Power Performance (EPP) label. Mixing PSUs from
previous generations servers is not supported, even if the PSUs have the same
power rating. This results in a PSU mismatch condition or failure to turn the
appliance on.
CAUTION:
When correcting a PSU mismatch, replace only the PSU with the
blinking indicator. Swapping the PSU to make a matched pair can result in an
error condition and unexpected appliance shutdown. To change from a High Output
configuration to a Low Output configuration or vice versa, you must turn off the
appliance.
CAUTION:
If two PSUs are used, they must be of the same type and have the same
maximum output power.
CAUTION:
Combining AC and DC PSUs is not supported and triggers a mismatch.
2. Hard drive status indicator
4. Hard drive
Condition
Identifying drive or preparing for removal.
Hard drive ready for removal.