Dell PowerEdge C1100 使用方法
Table 1-19. IPMI Settings
Settings
Enable IPMI Over LAN
Channel Privilege Level Limit
Encryption Key
Table 1-20. VLAN Settings
Settings
Enable VLAN ID
VLAN ID
Priority

Platform Events

All alert settings can be enabled or disabled. To change the setting for all alerts, perform the
following steps:
1 Enter all event actions and alerts.
2 To activate all alert settings that have been defined in the Set Platform Events window, mark
the Enable Platform Event Filter alerts checkbox.
3 To deactivate all alert settings that have been defined in the Set Platform Events window,
clear the Enable Platform Event Filter alerts checkbox.
4 Click Apply Changes.
The Platform Event Filters List displays the actions that execute when an event occurs. An event
occurs when the status of a system element is outside a set limit. The event list also indicates if an
alert is enabled or disabled for each event.
Table 1-21 provides the Actions and Alerts that can occur when an event is out of bounds. Only one
action can be set for each event.
Description
Enable IPMI LAN Channel
The maximum privilege level that can be accepted on the LAN
Channel.
Format: 0 to 20 bytes (even number of hexadecimal characters, no
blank spaces are allowed).
Description
If enabled, only matched VLAN ID traffic is accepted.
VLAN ID field of 802.1g fields. Enter a valid value for Virtual LAN ID
(must be a number from 1 to 4094).
Priority field of 802.1g fields. Enter a number from 0 to 7 to set the
Priority of the Virtual LAN ID.
Using the Baseboard Management Controller
19